| Defects | Cause | Solutions |
| 1. The depth of the formed blisters is not deep enough. | 1. The depth of forming is not correct. | 1. Adjust the Adjustable Nut (13, 15) of the cold forming mechanism downwards, using the Vernier Caliper to measure the formed blister depth, and make it 0.3- 0.5 mm deeper than the medicine’s thickness. |
| 2. The formed blister depth is not uniform. | 1. The Forming Up Mould and Forming Low Mould are not parallel. | 1. Using the Vernier Caliper to measure the 4 sides’ distance between the lower surface of the Forming Up Mould (17) and the upper surface of the Forming Low Mould (18), the difference should be less than 0.1mm. |
| 3. The formed blisters are breached. | 1 . Forming depth is too deep. 2 . Aluminum foil elongation property is not enough. | 1. Reduce forming depth 2. Change the aluminum foil to one that has enough elongation property. |
| 4. Wrinkles on the surface of the formed blisters. | 1. Forming depth is too deep. 2 . The pressure is not high enough between the Press Plate Mould and Forming Low Mould. | 1. Reduce the forming depth 2. Lower the position of the low and up Adjustable Nut (11), make larger pressure between Press Plate Mould (12) and Forming Low Mould (18). |