Project Overview
An Algerian pharmaceutical manufacturer has initiated comprehensive technical and commercial evaluations for an integrated solid-dosage processing and packaging line. The project encompasses high-speed capsule filling, platen-sealing blister packaging, and intermittent cartoning operations configured for regional deployment.
Core Technical Portfolio
Capsule Filling (NJP-1200C): Configured for multi-product dosing of powders, pellets, and granules, achieving an output capacity of 70,000 to 80,000 capsules per hour. Includes dedicated format change sets for capsule sizes 00, 0, and 2, complete with integrated dust collection systems and vacuum pumps.
Blister Packaging Machine: Utilizes a platen-sealing architecture optimized for high-precision flat-web forming and thermal sealing, delivering a throughput rate of 200 to 300 blister cards per minute.
Cartoning Machine: Employs an intermittent-motion cartoning system engineered for stable secondary packaging at an output of 150 cartons per minute.
Automation & Component Architecture
Control & HMI Systems: Powered by Mitsubishi PLC, VFD (inverter), and HMI platforms featuring English-language operational software compliant with 21 CFR Part 11 electronic records regulations.
Pneumatics & Electrical: Incorporates FESTO pneumatic valves, cylinders, and fittings. All control buttons, switches, and HMI text interfaces are explicitly localized in English.
Electrical Supply: Configured for standard industrial power distribution at 380 VAC, 50 Hz.
Material Compliance & Validation Framework
Construction & Finishes: All product-contact components are fabricated from AISI 316L stainless steel backed by certified material documentation, while non-contact structural frames utilize AISI 304 stainless steel.
Validation Package: Includes comprehensive compliance documentation comprising Design Qualification (DQ), Installation Qualification (IQ), and Operation Qualification (OQ) protocols.
Commercial & Spares Scope: Incorporates a one-year critical spare parts inventory, equipment identification nameplates, English-language technical manuals, and C&F commercial shipping terms to Algiers seaport.