Project Inquiry: URS for High-Speed Blister Packaging Machine (Serbia)

Project Overview: A pharmaceutical and dietary supplement manufacturer based in Serbia has submitted a formal User Requirement Specification (URS) for a high-speed blister packaging machine. The equipment is designated for a first-floor facility and must comply with rigorous European GMP standards, requiring versatile material handling, comprehensive validation, and localized documentation.

1. Production Capacity & Technical Specifications
The core mechanical and output requirements mandate a highly flexible and efficient system:

  • Target Output: Fully automatic operation yielding 170 to 200 blisters per minute.
  • Material Flexibility: Hybrid processing capabilities for both thermoforming (PVC/Alu, PVDC/Alu) and cold-forming (Alu/Alu) operations.
  • Blister Format: 65 mm × 90 mm blister dimensions configured for 10 capsules per card.
  • Tooling Agility: Rapid format changeover design, with tooling removal and replacement times strictly under 30 minutes.
  • Material Standards: All product-contact components must be manufactured from pharmaceutical-grade AISI 316L stainless steel.

2. Automation, Quality Control & Safety
The URS outlines strict requirements for automated inspection and operational safety:

  • Quality Inspection: Automated detection and separation/rejection of empty or poorly sealed blisters, alongside accurate production counting.
  • HMI Architecture: A comprehensive display terminal for inputting operational parameters, real-time machine diagnostics, and overall system control.
  • Safety Interlocks: Integrated protection systems programmed to execute an automatic machine halt upon detecting operational irregularities, mechanical faults, or pneumatic supply drops.

3. GMP Validation & Service Level Agreement (SLA)
To satisfy regulatory compliance and ensure long-term operational stability, the procurement includes stringent validation and after-sales terms:

  • Validation Protocols: Execution of Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ) during the commissioning and handover phase.
  • Bilingual Documentation: All technical data sheets, operating manuals, and maintenance instructions must be provided in both Serbian and English.
  • Service Guarantee: A comprehensive 2-year warranty covering on-site assessment and repair for manufacturing defects, combined with operator training, rapid-response maintenance SLA, and guaranteed spare parts availability.