Equipment: Integrated Blister Line (DPP260L Blister Machine & ZH180 Cartoner)
Client: Novartis Subsidiary
Record Date: 10/07/2014
The operational specification required the loading of two distinct vial formats into a single blister card. Post-sealing, the blister cards necessitated a continuous motion transfer to the cartoning unit to achieve a sustained output of 180 cartons per minute. The primary mechanical constraint was the feeding station, which demanded high-speed, dual-format sorting and loading within a highly restricted physical platform area to maintain synchronization with the downstream cartoner.
To resolve the feeding synchronization constraints, the finalized line integrates the DPP260L Blister Machine with the ZH180 Cartoner, utilizing a dedicated EPSON robotic arm as the primary feeding mechanism. Following a four-month engineering and assembly phase, the integrated system underwent a 30-day stability testing protocol. The robotic feeding and continuous motion transfer mechanisms performed within specified tolerances, fulfilling the dual-vial handling and throughput requirements.