Engineering Evaluation: Alu-Alu Blister Packaging with Partial Sealing for ETO Sterilization
10/07/2018
Project Overview: A medical device manufacturer based in Karachi, Pakistan, initiated an engineering inquiry for a compact Alu-Alu blister packaging system. The equipment is designated for a newly established manufacturing facility specializing in surgical sutures, requiring precise cold-forming capabilities and a specialized two-stage sealing process to accommodate sterilization protocols.
1. Primary Packaging and Cold Forming
The surgical sutures are initially wound onto a rigid plastic carrier (referred to as a “race track pack”). This carrier is subsequently enclosed within an Alu-Alu blister. The primary blister machine must execute an asymmetric cold-forming sequence, wherein the bottom aluminum web is deep-drawn to accommodate the carrier’s geometry, while the top lidding foil remains entirely flat.
2. Partial Sealing for ETO Sterilization
A critical mechanical requirement of the primary blister machine is the execution of a partial seal. The sealing station must be engineered to hermetically seal only three sides of the blister perimeter, deliberately leaving a 16mm unsealed lip at the bottom edge. This specific configuration is mandatory to allow gas penetration during the subsequent Ethylene Oxide (ETO) sterilization phase.
3. Post-Sterilization Secondary Sealing
Following the ETO sterilization cycle, the unsealed lip must be closed under sterile conditions. The project scope requires a secondary, manually operated thermal sealing unit. This auxiliary equipment must feature a compact, highly cleanable architecture suitable for integration within a laminar flow hood, ensuring isolated closure of each individual pack.
Engineering Assessment: JORNEN’s engineering team is currently designing a customized sealing mold for the primary Alu-Alu blister machine to execute the precise 3-sided seal and 16mm lip. Concurrently, technical specifications for a GMP-compliant, medical-grade secondary benchtop sealer are being evaluated for the laminar flow cleanroom integration.