Engineering Case: Benchtop R&D Blister Machine with Multi-Format Thermoforming

A Singapore-based technical integrator submitted a comprehensive engineering specification for a highly versatile, benchtop blister packaging machine. The system is intended for R&D or pilot-scale production (180 to 200 cycles per hour), requiring multi-format capabilities for both thermoforming and cold-forming of solid and liquid reagents. The unit must function as a standalone platform executing a complete 3-in-1 sequence—forming, sealing, and cutting—within a maximum footprint of 550mm (H) x 652mm (W) x 715mm (D).
1. Broad-Spectrum Material Compatibility
The specification mandates broad adaptability across pharmaceutical-grade webs:

  • Forming Webs: Standard polymers (PVC, PVDC, PP, PS) and ultra-high barrier composites including Aclar, PVC-CTFE, and cold-formed OPA/ALU/PVC (Triplex).
  • Lidding Foils: Hard and soft aluminum, Tyvek, and Paper-PET laminates. Lidding primers and inks must withstand sealing temperatures up to 300°C without degradation, supporting both push-through and peel-off opening mechanisms.
2. Critical Operational Parameters
The mechanical configuration must support a maximum format area of 180x120mm with forming depths precisely adjustable between 2mm and 12mm.

  • Thermal & Pneumatic Control: Heating modules require control up to 250°C (±5% accuracy in 1°C increments). Pneumatic sealing pressure must be regulatable between 0.1 and 0.6 MPa.
  • Atmospheric Purging: A bespoke oxygen purging system must be integrated to displace ambient air, achieving a strict 0% (±2%) internal oxygen level prior to the sealing phase.
  • Rapid Tooling Changeover: Complete tooling transitions must be achievable within 20 minutes (including a 15-minute thermal warmup). Tooling architectures utilize tool-less, plug-in pneumatic and electrical fittings.
3. GMP Compliance and Safety Integration
Engineered for strict pharmaceutical compliance, the machine surfaces must be smooth and free of sharp edges to facilitate rapid line clearance without concealing products. Safety features include an emergency stop with an automatic pneumatic dump valve, safety-interlocked transparent guarding, and thermal insulation restricting external case temperatures to a maximum of 50°C. Operating noise is capped at 75 dB(A).
JORNEN’s engineering department is currently evaluating the integration of the oxygen purging mechanism and the diverse tooling requirements to formulate a technical proposal. The final delivery will encompass full Installation Qualification (IQ) and Operational Qualification (OQ) protocols, alongside comprehensive construction and test records to satisfy the client’s validation standards.