Home / Newsroom / Comprehensive Troubleshooting Guide & FAQs for Blister Packaging Machines
Comprehensive Troubleshooting Guide & FAQs for Blister Packaging Machines
08/08/2013
With varying manufacturing standards globally, the performance and design of blister packaging machines can differ significantly. Generally, based on their core structural design, these machines are classified into three categories: Platen-Type, Rotary-Type, and Platen-Rotary Type.
Understanding the mechanical differences is crucial. For instance, in the blister forming process, platen-type machines utilize positive air pressure, which consistently yields superior, more uniform cavity definition compared to the vacuum forming typical of rotary types. Conversely, rotary sealing mechanisms are often praised for their continuous high-speed sealing capabilities.
During daily pharmaceutical production, operators may occasionally encounter challenges with blister forming or heat sealing. Below is a professional troubleshooting guide to help you identify and resolve these common issues rapidly.
I. Troubleshooting Blister Forming Defects
If the blister cavities are poorly formed, misaligned, or ruptured, perform the following checks:
Material Quality: Verify that the specifications and quality of the forming film (e.g., PVC, PVDC, or Alu-Alu) meet production requirements.
Heating Temperature: Ensure the heating station is calibrated to the appropriate temperature for the specific material.
Heater Surface: Inspect the heating plates to ensure no melted PVC residue is adhering to the surface.
Mold Integrity: Check the forming molds. The cavities must be perfectly smooth, and all exhaust air holes must be unobstructed.
Cooling Efficiency: Confirm that the forming mold’s cooling system (chilled water circulation) is operating optimally.
Rotary Machine Specifics: Check if the vacuum degree and negative pressure exhaust rates are within normal ranges. Inspect pneumatic pipelines for leaks or abnormal wear.
Platen Machine Specifics: Ensure the positive compressed air is clean and completely dry. Verify that the air pressure and flow rates meet operational standards, and check pipelines for damage.
Mold Parallelism (Platen): Ensure the upper and lower forming molds are perfectly parallel to guarantee uniform clamping force and prevent air leakage during forming.
II. Troubleshooting Heat Sealing Defects
If you encounter weak seals, curled edges, or wrinkled foil, proceed with these inspection steps:
Foil & Coating: Inspect the lidding material (Aluminum foil). Ensure the heat-seal lacquer (thermosol) is evenly coated and of acceptable quality.
Sealing Temperature: Verify that the heat-sealing station is set to the optimal temperature for the selected materials.
Web Tension: Check the unwinding path of both the forming web and the lidding foil to ensure there is no abnormal mechanical resistance or tension variation.
Mold Alignment: Inspect the heat-sealing molds. The surface must be pristine, and the formed blister pockets must align and insert seamlessly into the sealing mold cavities.
Knurling Pattern: Examine the grid pattern (knurling) on the heating plate. It should be distinct, clean, and consistent in depth.
Cooling System: Verify that the cooling mechanism for the heat-sealing station is functioning efficiently to prevent foil warping.
Sealing Pressure: Ensure the pneumatic or mechanical pressure applied during the sealing phase meets the required specifications.
Parallelism: Confirm absolute parallelism between the upper and lower heat-sealing molds to ensure uniform pressure across the entire web width.
III. Advanced Automatic Monitoring & Safety Systems
Modern, high-tier blister packaging machines are equipped with sophisticated PLC-controlled monitoring devices. These systems automatically protect the machinery and trigger alarms (or halt production) upon detecting the following anomalies:
Safety Interlock: A safety protective door or acrylic cover is opened during operation.
Air Supply Drop: Compressed air pressure falls below the safe operational threshold.
Temperature Deviation: Heating zones fail to reach or maintain the set temperature.
Material Depletion: The machine runs out of forming film (PVC/Alu) or lidding foil.
Product Shortage: Depletion of tablets/capsules/vials in the automated feeding hopper.
Mechanical Overload: Abnormal torque or mechanical overload detected at any specific workstation.
Electrical Fault: Circuit overload or power instability.
Conclusion: While this guide covers the most common scenarios, actual production environments are complex. Finding the root cause requires concrete, step-by-step analysis. As a dedicated provider of pharmaceutical packaging machinery since 1986, Jornen is committed to delivering robust equipment and comprehensive technical support to keep your production running flawlessly.