Home / Newsroom / R&D Lab-Scale Tablet Compression Machine URS from Pakistan
R&D Lab-Scale Tablet Compression Machine URS from Pakistan
01/08/2017
Project Overview
A pharmaceutical enterprise based in Pakistan has issued a comprehensive User Requirements Specification (URS) for an R&D lab-scale tablet compression machine. The equipment is designated for multi-format formulation testing, continuous process monitoring, and the integration of Process Analytical Technology (PAT) within a predefined 2600 x 2800 x 2500 mm laboratory footprint.
Core Mechanical & Tooling Scope
Tooling Architecture: Requires a keyed turret compatible with EU B and D type tooling (4-6 punches), accommodating tablet diameters from 6 mm to 20 mm. The system must execute both single and double-layer compression sequences without necessitating a complete turret exchange.
Compression & Drive Dynamics: Mandates a minimum compression force of 3 KN, driven by a variable speed main motor operating at 60-80 rpm with integrated overload protection. Both pre-compression and main compression forces must be continuously monitored and recorded via an integrated data logger.
Structural Integrity: The mechanical design must feature complete zone isolation to prevent powder spillage into the lower mechanical compartment. Construction must be entirely rust-free and solid (excluding cladding, chrome plating, or acrylic), ensuring zero dead ends for powder accumulation and maintaining operational noise below 80 dB.
Process Control & PAT Integration
Feeding & Analytical Integration: Evaluates a force-feed powder/granular handling